home *** CD-ROM | disk | FTP | other *** search
/ Collection of Tools & Utilities / Collection of Tools and Utilities.iso / dskut / easydiag.zip / EASYDIAG.TXT < prev    next >
Text File  |  1989-07-06  |  2KB  |  69 lines

  1.         AT User Diagnostics Revision History
  2.  
  3.  
  4.     Written: First pass, March 1989 by Western Digital Corp.
  5.  
  6.     Purpose: Allow quick, easy and thorough AT hard disk controller
  7.          and hard disk diagnostics.
  8.  
  9.     Compatability : All Western Digital AT register compatible
  10.             controllers.
  11.         
  12.     Program Name :    EASYDIAG.EXE  (previous versions USERDIAG.EXE)
  13.         
  14.  
  15.     1) REPORTS CORRECTABLE DATA ERRORS ... Previous versions
  16.        relied on a test of the STATUS register ONLY. USERDIAG
  17.        also has this limitation. If a correctable data error
  18.        is encountered, the test terminates and waits for
  19.        operator input.
  20.         
  21.     2) COMPLETE DOCUMENTATION ............ Details both the
  22.        (U)ser selected advanced test and the (A)utomatic
  23.        quick test. Error messages are verbosely explained in the
  24.        (A)utomatic quick test section of the document.
  25.         
  26.     3) COMMAND TIMEOUTS .................. Have been extended
  27.        to almost a minute on a 12Mhz AT (WDM20). This will
  28.        allow for 33Mhz 80386's with cache and controllers that
  29.        issue SLOW recals.
  30.         
  31.     4) ID FIELD RETRIES DISABLED AT ALL TIMES.
  32.         
  33.     5) STRAIGHT-LINE DRQ SERVICE .......... READ DRQ loop does not
  34.        store data (Write/Read Verify loop does, but more efficiently)
  35.        Complete test consisting of a re(Z)ero, 256 RANDOM seeks,
  36.        256 RANDOM two-sector reads, and 50 RANDOM data pattern
  37.        (W)rite / Read Verifies of last track takes approximately
  38.        30 sec. (CDC WREN II, 10 Mhz AT)
  39.  
  40.     6) BAD BLOCK ERRORS IGNORED .......... These errors are
  41.        reported to screen, but testing continues. This is the
  42.        ONLY error that is tolerated in the (A)utomatic or
  43.        (U)ser defined test menus.
  44.  
  45.     IMPROVEMENTS OF EZDIAG.EXE OVER USERDIAG.EXE
  46.         
  47.         EZDIAG                    USERDIAG
  48.         
  49.     Automatic Quick Test                N/A
  50.     Dual test menu ... AUTO + SPECIFIC        Specific (A)ll Test
  51.     Bad Block Errors allowed            Terminates test
  52.     Retries Disabled                Retries enabled
  53.     ECC Correctable Errors reported            NOT REPORTED
  54.     Straight-line DRQ service loop            Iterative loop
  55.     Exit to DOS from DIAG menu            N/A
  56.     Default sector count = 1            Default = 256
  57.     Congratulatory message                "command successful"
  58.     Single keystroke test selection         Return required
  59.  
  60.  
  61.     Please forward any questions or suggestions to the SYSOP of
  62.     this BBS.
  63.  
  64.         
  65.     Regards,
  66.         
  67.     Mel Butler
  68.     WDC Dallas
  69.